Mfg Part Number: 21-489013-200
Alternate P/N: 21489013200
NSN : 5915-01-163-2549
NIIN : 011632549
CAGE Code : 77820
Manufacturer: Amphenol Corporation
Item Name : Filter Radio Frequency Interfere
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like 21-489013-200 for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Filter Radio Frequency Interfere from Amphenol Corporation with Cage Code 77820 as well as part numbers like 21-489013-200 and FSC 5915 Filters and Networks with011632549. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like 21-489013-200 and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5915011632549 from manufacturers like Amphenol Corporation. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-163-2549 Item Description: Filter Radio Frequency Interfere | 5915 | 011632549 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | G | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
21-489013-200 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.012 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.125 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.125 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.126 INCHES MINIMUM AND 0.132 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.906 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+500.0 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.906 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 5TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 6TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 1ST RADIO INTERFERENCE AND 2.0 VOLTS DC 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 2ND RADIO INTERFERENCE AND 2.0 VOLTS DC 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 3RD RADIO INTERFERENCE AND 2.0 VOLTS DC 3RD RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 4TH RADIO INTERFERENCE AND 2.0 VOLTS DC 4TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 5TH RADIO INTERFERENCE AND 2.0 VOLTS DC 5TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 1.2 VOLTS AC 6TH RADIO INTERFERENCE AND 2.0 VOLTS DC 6TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 71468 |
AHBP | INPUT TERMINAL IDENTIFICATION | MIL-C-38999 |
AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 71468 |
AHBT | OUTPUT TERMINAL IDENTIFICATION | MIL-C-38999 |
AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AHCJ | FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.1 AND 1.0 AND 2.0 AND 10.0 AND 100.0 AND 1000.0 |
AHCK | FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 2.0 AND 10.0 AND 16.0 AND 40.0 AND 75.0 AND 90.0 |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | MOISTURE RESISTANT AND SHOCK RESISTANT |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 46 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT |
CQDZ | MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 300.0 VOLTS AT SEA LEVEL |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 200.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 200.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AND 200.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION AND 200.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION AND 200.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 120.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION AND 200.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQRG | BODY MATERIAL | ALUMINUM |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 300.0 VOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | CADMIUM |
FEAT | SPECIAL FEATURES | TWENTY-TWO FILTERED FUNCTIONS; TWENTY-FOUR UNFILTERED FUNCTIONS |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |
PRMT | PRECIOUS MATERIAL | GOLD |
STYL | STYLE DESIGNATOR | FILTER CONNECTOR |