Mfg Part Number: 6181559-008
Alternate P/N: 6181559008
NSN : 5915-01-330-0553
NIIN : 013300553
CAGE Code : 14283
Manufacturer: Amphenol Optimize Manufacturing Co
Item Name : Filter Radio Frequency Interfere
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like 6181559-008 for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Filter Radio Frequency Interfere from Amphenol Optimize Manufacturing Co with Cage Code 14283 as well as part numbers like 6181559-008 and FSC 5915 Filters and Networks with013300553. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like 6181559-008 and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5915013300553 from manufacturers like Amphenol Optimize Manufacturing Co. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-330-0553 Item Description: Filter Radio Frequency Interfere | 5915 | 013300553 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | G | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6181559-008 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.187 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.710 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.710 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.271 INCHES NOMINAL |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 3RD RADIO INTERFERENCE AND 8.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 4TH RADIO INTERFERENCE AND 8.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 5TH RADIO INTERFERENCE AND 8.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 6TH RADIO INTERFERENCE AND 8.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBN | III INPUT TERMINAL MANUFACTURER CODE | 59610 |
AHBS | III OUTPUT TERMINAL MANUFACTURER CODE | 59610 |
AHCG | III MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AHCJ | III FULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ | 0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE ALL FUNCTIONS |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE AND 800.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 4TH RADIO INTERFERENCE AND 800.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 5TH RADIO INTERFERENCE AND 800.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 6TH RADIO INTERFERENCE AND 800.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
FEAT | SPECIAL FEATURES | THIRTY-TWO FILTERED FUNCTIONS WITH X-TYPE INSERT POSITION |
PMLC | III PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |
PRMT | III PRECIOUS MATERIAL | GOLD |
STYL | STYLE DESIGNATOR | FILTER CONNECTOR |
AFGA | III OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE 6TH FUNCTION |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
CRDC | III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.2 KILOVOLTS AT SEA LEVEL |
CRST | III BODY SURFACE TREATMENT | CADMIUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.271 INCHES NOMINAL |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHCK | III FULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS | 3.0 AND 10.0 AND 10.0 AND 10.0 AND 50.0 AND 50.0 |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 32 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT ALL FUNCTIONS |
AECR | III VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 500.0 |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 1ST RADIO INTERFERENCE AND 8.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 2ND RADIO INTERFERENCE AND 8.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBP | III INPUT TERMINAL IDENTIFICATION | MIL-C-26482 |
AHBT | III OUTPUT TERMINAL IDENTIFICATION | MIL-C-26482 |
CBBL | FEATURES PROVIDED | MOISTURE RESISTANT AND SHOCK RESISTANT |
CQDZ | III MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 1.2 KILOVOLTS AT SEA LEVEL |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE AND 800.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 3RD RADIO INTERFERENCE AND 800.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQRG | III BODY MATERIAL | ALUMINUM |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote