Mfg Part Number: 85073
NSN : 5950-00-838-1924
NIIN : 008381924
CAGE Code : 94117
Item Name : Transformer Pulse
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like 85073 for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Transformer Pulse from Bae Systems Information And Electronic Systems Integration Inc with Cage Code 94117 as well as part numbers like 85073 and FSC 5950 Coils and Transformers with008381924. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like 85073 and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5950008381924 from manufacturers like Bae Systems Information And Electronic Systems Integration Inc. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-838-1924 Item Description: Transformer Pulse | 5950 | 008381924 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
85073 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
PULSE | ABMK | OVERALL WIDTH2 750 INCHES MAXIMUM |
PULSE | ACYW | IMPEDANCE RATING IN OHMS1140 0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
PULSE | ACZH | PRIMARY TO SECONDARY TURN RATIO1 TO 6-12 SINGLE COMPONENT |
PULSE | ACZN | PULSE REPETITION RATE300 0 HERTZ SINGLE COMPONENT |
PULSE | AKNA | INCLOSURE TYPEHERMETICALLY SEALED |
PULSE | AKPV | MOUNTING FACILITY QUANTITY4 SINGLE GROUP |
PULSE | AXGY | MOUNTING METHODTHREADED STUD SINGLE GROUP |
PULSE | CMLP | THREAD QUANTITY PER INCH32 SINGLE GROUP |
PULSE | CRBZ | WINDING OPERATING CURRENT1 75 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
PULSE | THSD | THREAD SERIES DESIGNATORUNC SINGLE GROUP |
PULSE | AARG | RELIABILITY INDICATORNOT ESTABLISHED |
PULSE | ABHP | OVERALL LENGTH2 375 INCHES MAXIMUM |
PULSE | ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1 750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
PULSE | ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2 125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
PULSE | ADAU | BODY HEIGHT3 812 INCHES MAXIMUM |
PULSE | BPLC | WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
PULSE | CQJX | NOMINAL THREAD SIZE0 138 INCHES SINGLE GROUP |
PULSE | TTQY | TERMINAL TYPE AND QUANTITY5 TAB SOLDER LUG |