Mfg Part Number: 400932
NSN : 5950-00-069-8161
NIIN : 000698161
CAGE Code : 0AHP5
Manufacturer: Curtiss Wright Controls Inc
Item Name : Transformer Power
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like 400932 for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Transformer Power from Curtiss Wright Controls Inc with Cage Code 0AHP5 as well as part numbers like 400932 and FSC 5950 Coils and Transformers with000698161. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like 400932 and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5950000698161 from manufacturers like Curtiss Wright Controls Inc. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-069-8161 Item Description: Transformer Power | 5950 | 000698161 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
400932 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.203 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.750 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.750 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.750 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.125 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY AND 1.25 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY AND 1.375 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 112.5 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY AND 125.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY AND 137.5 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.15 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY AND 3.5 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY AND 3.85 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 0.25 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY AND 76.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY AND 84.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.25 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 56.25 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 68.75 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 1.25 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 22.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY AND 27.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 112.10 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 118.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 123.90 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 3.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 22.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 27.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 21 TAB, SOLDER LUG |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote