Mfg Part Number: RX826
NSN : 5950-01-476-6155
NIIN : 014766155
CAGE Code : 13619
Manufacturer: Ems Development Corporation
Item Name : Transformer Pulse
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like RX826 for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Transformer Pulse from Ems Development Corporation with Cage Code 13619 as well as part numbers like RX826 and FSC 5950 Coils and Transformers with014766155. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like RX826 and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5950014766155 from manufacturers like Ems Development Corporation. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-476-6155 Item Description: Transformer Pulse | 5950 | 014766155 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Rx826 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 12.720 INCHES MINIMUM AND 12.780 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 14.280 INCHES MINIMUM AND 14.310 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 7.220 INCHES MINIMUM AND 7.280 INCHES MAXIMUM |
ACYW | IMPEDANCE RATING IN OHMS | 13.9 NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
ACYW | IMPEDANCE RATING IN OHMS | 1390.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
AGAV | END ITEM IDENTIFICATION | AN/TSP-75; WSD: TACTICAL AIR CONTROL SYSTEMS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 8 ALL GROUPINGS |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 20 ALL GROUPINGS |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES ALL GROUPINGS |
CRBZ | WINDING OPERATING CURRENT | 84.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CRBZ | WINDING OPERATING CURRENT | 840.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 11.70 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 117.00 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 12.720 INCHES MINIMUM AND 12.780 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 14.280 INCHES MINIMUM AND 14.310 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 7.220 INCHES MINIMUM AND 7.280 INCHES MAXIMUM |
ACYW | IMPEDANCE RATING IN OHMS | 13.9 NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
ACYW | IMPEDANCE RATING IN OHMS | 1390.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
AGAV | END ITEM IDENTIFICATION | AN/TSP-75; WSD: TACTICAL AIR CONTROL SYSTEMS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 8 ALL GROUPINGS |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 20 ALL GROUPINGS |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES ALL GROUPINGS |
CRBZ | WINDING OPERATING CURRENT | 84.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
CRBZ | WINDING OPERATING CURRENT | 840.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 11.70 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT |
CWJS | WINDING OPERATING VOLTAGE | 117.00 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |