Mfg Part Number: AA11A223A
NSN : 5910-01-045-0120
NIIN : 010450120
CAGE Code : 06001
Manufacturer: General Electric Company
Item Name : Capacitor Fixed Plastic Dielectr
FSC : FSC 5910 Capacitors
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like AA11A223A for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Capacitor Fixed Plastic Dielectr from General Electric Company with Cage Code 06001 as well as part numbers like AA11A223A and FSC 5910 Capacitors with010450120. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like AA11A223A and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5910010450120 from manufacturers like General Electric Company. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-045-0120 Item Description: Capacitor Fixed Plastic Dielectr | 5910 | 010450120 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Aa11a223a | 1 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.000 INCHES MINIMUM |
ADAQ | BODY LENGTH | 0.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.471 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.234 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.400 INCHES NOMINAL |
AEBT | TERMINAL DIAMETER | 0.032 INCHES NOMINAL |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
AFHW | INTERNAL ELECTRICAL CONNECTION TYPE | EXTENDED FOIL |
CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 30000.0 MEGOHMS |
CQBQ | CAPACITANCE VALUE PER SECTION | 0.022 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 200.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -5.00/+5.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 300000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.3000 |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
CWSS | DIELECTRIC MATERIAL | PLASTIC POLYESTER |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote