Mfg Part Number: TDC476K020CL
NSN : 5910-00-422-5277
NIIN : 004225277
CAGE Code : 90201
Manufacturer: Mallory Sonalert Products Inc
Item Name : Capacitor Fixed Electrolytic
FSC : FSC 5910 Capacitors
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like TDC476K020CL for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Capacitor Fixed Electrolytic from Mallory Sonalert Products Inc with Cage Code 90201 as well as part numbers like TDC476K020CL and FSC 5910 Capacitors with004225277. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like TDC476K020CL and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5910004225277 from manufacturers like Mallory Sonalert Products Inc. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-00-422-5277 Item Description: Capacitor Fixed Electrolytic | 5910 | 004225277 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Tdc476k020cl | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, RADIAL TERMINALS |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.450 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.250 INCHES MAXIMUM |
AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.220 INCHES MINIMUM AND 0.280 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
AECE | ANODE TYPE | SOLID |
AECQ | ELECTRICAL POLARIZATION | POLARIZED |
CQBQ | CAPACITANCE VALUE PER SECTION | 47.000 MICROFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQLH | DC LEAKAGE AT MAXIMUM OPERATING TEMP | 150.0 MILLIAMPERES |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 20.0 DC SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION |
CWJK | CASE MATERIAL | PLASTIC |
CWNJ | CAPACITIVE ELECTRODE MATERIAL | TANTALUM |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 8.0000 |
CWQH | DC LEAKAGE AT REFERENCE TEMP | 15.000 MICROAMPERES |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |