Mfg Part Number: 2636996G005
NSN : 5985-01-394-6442
NIIN : 013946442
CAGE Code : 63661
Manufacturer: Microwave Development Company Inc
Item Name : Waveguide Assembly
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like 2636996G005 for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Waveguide Assembly from Microwave Development Company Inc with Cage Code 63661 as well as part numbers like 2636996G005 and FSC 5985 Antennas Waveguides and Related Equipment with013946442. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like 2636996G005 and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5985013946442 from manufacturers like Microwave Development Company Inc. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-394-6442 Item Description: Waveguide Assembly | 5985 | 013946442 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2636996g005 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AHSZ | Flange Outside Width | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTA | Flange Outside Height | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTN | Flange Connecting Hole Diameter | 0.144 INCHES MINIMUM FIRST FLANGE ALL CONNECTION FACILITIES AND 0.147 INCHES MAXIMUM FIRST FLANGE ALL CONNECTION FACILITIES |
AHTW | Voltage Standing Wave Ratio | 1.18 |
AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
MRC | Decoded Requirement | Clear Text Reply |
FLEX | Flexibility | RIGID SINGLE TUBING SEGMENT |
AAJF | Thread Direction | RIGHT-HAND SECOND FLANGE ALL CONNECTION FACILITIES |
CSQT | Flange Connecting Facility And Quantity | 4 UNTHREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CSQT | Flange Connecting Facility And Quantity | 4 THREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
MATT | Material | ALUMINUM ALLOY SINGLE TUBING SEGMENT AND FLANGE |
AAJD | Thread Class | 2B SECOND FLANGE ALL CONNECTION FACILITIES |
CQHN | Waveguide Outside Width | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
THSD | Thread Series Designator | UNC SECOND FLANGE ALL CONNECTION FACILITIES |
CRFH | Waveguide Inside Width | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
CWBG | Waveguide Offset Distance | 4.000 INCHES NOMINAL |
STYL | Style Designator | BEND TYPE |
CQJX | Nominal Thread Size | 0.164 INCHES SECOND FLANGE ALL CONNECTION FACILITIES |
CTCJ | Flange Style | CHOKE TYPE SECOND FLANGE |
CTCJ | Flange Style | COVER TYPE FIRST FLANGE |
CRLB | Waveguide Inside Height | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |
AHRV | Tubing Wall Construction Style | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | Flange Quantity | 2 |
FEAT | Special Features | 8.2 TO 12.4 GHZ FREQUENCY; 250 WATTS CW; 1.5 KW PEAK POWER |
CSFC | Waveguide Outside Height | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
AHSY | Flange Inside Height | 0.396 INCHES MINIMUM SECOND FLANGE AND 0.404 INCHES MAXIMUM SECOND FLANGE |
AHSZ | Flange Outside Width | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHTA | Flange Outside Height | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
CSPL | Waveguide Longer Offset Distance | 4.000 INCHES NOMINAL |
AHTD | Flange Depth | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHSY | Flange Inside Height | 0.503 INCHES MINIMUM FIRST FLANGE AND 0.506 INCHES MAXIMUM FIRST FLANGE |
AHTD | Flange Depth | 0.144 INCHES MINIMUM FIRST FLANGE AND 0.147 INCHES MAXIMUM FIRST FLANGE |
AHSX | Flange Inside Width | 0.896 INCHES MINIMUM SECOND FLANGE AND 0.904 INCHES MAXIMUM SECOND FLANGE |
AHSX | Flange Inside Width | 1.003 INCHES MINIMUM FIRST FLANGE AND 1.006 INCHES MAXIMUM FIRST FLANGE |
AHTX | Insertion Loss In Decibels | 0.12 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote