Mfg Part Number: 6181559-003
Alternate P/N: 6181559003
NSN : 5915-01-329-4302
NIIN : 013294302
CAGE Code : 15090
Manufacturer: Raytheon Company
Item Name : Filter Radio Frequency Interfere
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like 6181559-003 for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Filter Radio Frequency Interfere from Raytheon Company with Cage Code 15090 as well as part numbers like 6181559-003 and FSC 5915 Filters and Networks with013294302. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like 6181559-003 and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5915013294302 from manufacturers like Raytheon Company. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-329-4302 Item Description: Filter Radio Frequency Interfere | 5915 | 013294302 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | G | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6181559-003 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.155 INCHES MINIMUM AND 2.219 INCHES MAXIMUM |
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 5TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 1ST RADIO INTERFERENCE AND 8.0 VOLTS DC 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 3RD RADIO INTERFERENCE AND 8.0 VOLTS DC 3RD RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 5TH RADIO INTERFERENCE AND 8.0 VOLTS DC 5TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 59610 |
AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 59610 |
AHBT | OUTPUT TERMINAL IDENTIFICATION | MIL-C-26482 |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 10 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION AND 800.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION AND 800.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION AND 800.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION AND 800.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 1.2 KILOVOLTS AT SEA LEVEL |
FEAT | SPECIAL FEATURES | TEN FILTERED FUNCTIONS WITH 12-10P TYPE INSERT ARRANGEMENT |
PRMT | PRECIOUS MATERIAL | GOLD |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
CBBL | FEATURES PROVIDED | MOUNTING BRACKET AND SHOCK RESISTANT |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION AND 800.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 6TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 6TH RADIO INTERFERENCE AND 8.0 VOLTS DC 6TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBP | INPUT TERMINAL IDENTIFICATION | MIL-C-26482 |
CQRG | BODY MATERIAL | ALUMINUM |
CRST | BODY SURFACE TREATMENT | CADMIUM |
STYL | STYLE DESIGNATOR | FILTER CONNECTOR |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 2ND RADIO INTERFERENCE AND 8.0 VOLTS DC 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 2.5 VOLTS AC 4TH RADIO INTERFERENCE AND 8.0 VOLTS DC 4TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
CQDZ | MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 1.2 KILOVOLTS AT SEA LEVEL |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 250.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION AND 800.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACT SURFACES GOLD |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote