Mfg Part Number: 704192-1
Alternate P/N: 7041921
NSN : 5950-00-472-3590
NIIN : 004723590
CAGE Code : 96214
Manufacturer: Raytheon Company
Item Name : Transformer Power
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like 704192-1 for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Transformer Power from Raytheon Company with Cage Code 96214 as well as part numbers like 704192-1 and FSC 5950 Coils and Transformers with004723590. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like 704192-1 and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5950004723590 from manufacturers like Raytheon Company. To begin the purchasing process immediately, submit an RFQ today.
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.032 INCHES MINIMUM AND 2.032 INCHES MINIMUM AND 2.032 INCHES MINIMUM AND 2.032 INCHES MINIMUM AND 2.094 INCHES MAXIMUM2.094 INCHES MAXIMUM2.094 INCHES MAXIMUM2.094 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.484 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.484 INCHES MINIMUM SINGLE MO |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.234 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.234 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.234 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.234 INCHES MINIMUM SINGLE MO |
ABKW | OVERALL HEIGHT | 3.001 INCHES MINIMUM AND 3.001 INCHES MINIMUM AND 3.001 INCHES MINIMUM AND 3.001 INCHES MINIMUM AND 3.249 INCHES MAXIMUM3.249 INCHES MAXIMUM3.249 INCHES MAXIMUM3.249 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.719 INCHES MINIMUM AND 1.719 INCHES MINIMUM AND 1.719 INCHES MINIMUM AND 1.719 INCHES MINIMUM AND 1.781 INCHES MAXIMUM1.781 INCHES MAXIMUM1.781 INCHES MAXIMUM1.781 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT440.0 HERTZ MAXIMUM SINGLE COMPONENT440.0 HE |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 10.0 VOLT-AMPERE SINGLE COMPONENT10.0 VOLT-AMPERE SINGLE COMPONENT10.0 VOLT-AMPERE SINGLE COMPONENT10.0 VOLT-AMPERE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENTINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS130.0 DEG CELSIUS130.0 DEG CELSIUS130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALEDHERMETICALLY SEALEDHERMETICALLY SEALEDHERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT1 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 640.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 14.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK |