Mfg Part Number: 900-5X
Alternate P/N: 9005X
NSN : 5945-01-500-0568
NIIN : 015000568
CAGE Code : 18740
Manufacturer: Yale Industrial Products Ltd
Item Name : Relay Electromagnetic
If you’re in need of NSN parts, Purchasing Synergy is the ultimate source. As an ASAP Semiconductor company, we have access to a vast and diverse inventory of parts and components like 900-5X for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Relay Electromagnetic from Yale Industrial Products Ltd with Cage Code 18740 as well as part numbers like 900-5X and FSC 5945 Relays and Solenoids with015000568. Purchasing Synergy has more than two billion new and obsolete parts readily available with short lead times and competitive prices and, as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers a range of parametric search capabilities which allow our customers to search for parts through a number like 900-5X and filters, one of which is National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. Purchasing Synergy has a broad selection of NSN parts such as 5945015000568 from manufacturers like Yale Industrial Products Ltd. To begin the purchasing process immediately, submit an RFQ today.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-01-500-0568 Item Description: Relay Electromagnetic | 5945 | 015000568 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
900-5x | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.688 INCHES NOMINAL" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKW | OVERALL HEIGHT | 3.156 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.312 INCHES NOMINAL" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.172 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
AGAV | END ITEM IDENTIFICATION | MEP810A/B" |
AJSS | FREQUENCY IN HERTZ | 50.0 NOMINAL OR 60.0 NOMINAL" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY" |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC" |
FEAT | SPECIAL FEATURES | ENAME ON MFG DATA IS PHASE SEQUENCE RELAY; RELAY REMAINS DEENERGIZED WHEN APPLIED THREE PHASE VOLTAGE IS IN PROPER SEQUENCE AND IS ENERGIZED WHEN APPLIED THREE PHASE VOLTAGE IS IN INCORRECT SEQUENCE" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW ALL FUNCTIONS" |
ABHP | OVERALL LENGTH | 2.688 INCHES NOMINAL" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKW | OVERALL HEIGHT | 3.156 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.312 INCHES NOMINAL" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.172 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
AGAV | END ITEM IDENTIFICATION | MEP810A/B" |
AJSS | FREQUENCY IN HERTZ | 50.0 NOMINAL OR 60.0 NOMINAL" |
APNP | DUTY TYPE | CONTINUOUS" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY" |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC" |
FEAT | SPECIAL FEATURES | ENAME ON MFG DATA IS PHASE SEQUENCE RELAY; RELAY REMAINS DEENERGIZED WHEN APPLIED THREE PHASE VOLTAGE IS IN PROPER SEQUENCE AND IS ENERGIZED WHEN APPLIED THREE PHASE VOLTAGE IS IN INCORRECT SEQUENCE" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW ALL FUNCTIONS" |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote